Home > System Error > Loading The Teradata Icu Library Failed Error Is 126

Loading The Teradata Icu Library Failed Error Is 126

Contents

However, even if the ICU Libraries path is included in the system PATH environment variable, the libraries are not found by the Test Connection routine. Showing results for  Search instead for  Did you mean:  Teradata : Product Forums : Connectivity : ODBC Connectivity Issue Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Progress Software Corporation makes all reasonable efforts to verify this information. I've spent hours on this now and am getting frustrated. http://netlookmag.com/system-error/specified-driver-could-not-be-loaded-due-to-system-error-1114-a-dynamic-link-library.html

Like Show 0 Likes (0) Actions Re: Problems with Teradata ODBC connector Colin Albert Jan 14, 2015 9:58 AM (in response to Colin Albert ) You may also need to connect Like Show 0 Likes (0) Actions Re: Problems with Teradata ODBC connector Jayson Osmars Jan 14, 2015 8:52 AM (in response to Colin Albert ) aahhhh Let me check that one. Did this article solve your problem? Please tell us how we can make this article more useful.

Loading The Teradata Icu Library Failed Error Is 126

Odbc operation attempted: SQLDriverConnect. The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016. Warnings=11/14/2015 12:32:50.9131919 Warning Distribution to resources reported warnings.

The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016. The TPT connector starts the load but fails at the SQL select statement - with or with out data sense.Error:(2015-01-13 17:39:58) Error: QDSMain.Exceptions.DistributionFailedException: Distribute failed with errors to follow. ---> QDSMain.Exceptions.ReloadFailedException: Placing the libraries in c:\windows\system32 could cause more issues, because the installer doesn't originally install these libraries in c:\windows\system32 and doesn't know that they need to be removed during uninstallation. Specified Driver Could Not Be Loaded Due To System Error 126 Oracle Odbc Driver Make sure you have 64-bit TTU 13.0 (or later Efix on this release) Teradata ICU package installed. 0 Kudos Reply bkrywucki Fan Mark as New Bookmark Subscribe Subscribe to RSS Feed

I didn't have the ODBC connection set up on the publisher server. Specified Driver Could Not Be Loaded Due To System Error 126 (sql Server) installed.- Make sure you have a ODBC DSN created using 64-bit ODBC Administrator.- If you have installed Teradata pkgs. CAUSE: The Teradata ODBC driver installation is missing certain product dependencies on that machine. This document resolved my issue This document did not resolve my issue This document helped but additional information was required to resolve my issue What can we do to improve this

The entire risk arising out of the use or performance of the sample code is borne by the user. Specified Driver Could Not Be Loaded Due To System Error 127 All Rights Reserved. Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page vikrambharat N/A Mark as New Bookmark Subscribe Even restarted it just in case.

Specified Driver Could Not Be Loaded Due To System Error 126 (sql Server)

Error type: Odbc error. Glad to see that you have gotten further than myself as I am unable to locate 64-bit Windows ODBC driver. Loading The Teradata Icu Library Failed Error Is 126 I tried to look for the service bulletin at the site provided, but the site had no content. Loading The Teradata Sso Library Failed Error Is 127 Let me know if everyone has an idea to try or feedback to answer further inquiries.Thanks.Jayson 2207Views Tags: none (add) reloadContent tagged with reload, qlikview_serverContent tagged with qlikview_server, teradataContent tagged with

Showing results for  Search instead for  Did you mean:  Teradata : Product Forums : Connectivity : Error: SQL Error:Specified driver could not be loa... navigate here from http://www.teradata.com/DownloadCenter/Forum90-1.aspx 0 Kudos Reply u00jpl N/A Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Inappropriate Content ‎07-07-2011 09:58 AM ‎07-07-2011 DocumentPath=\\\\Test.qvw.(2015-01-13 17:39:58) Error: at QDSMain.ReloadTask.VerifyConditions(TaskResult taskResult)(2015-01-13 17:39:58) Error: at QDSMain.ReloadTask.Reload(String fileName, TaskResult taskResult, String sectionAccessUserName, String sectionAccessPassword, eReloadOptions reloadOption, String variableName, String variableValue, Boolean moniterCpuUsage)(2015-01-13 17:39:58) Error: --- End Your use of this Teradata website is governed by the Privacy Policy and the Terms of Use, including your rights to materials on this website, the rights you grant to your Specified Driver Could Not Be Loaded Due To System Error 193

Your use of this Teradata website is governed by the Privacy Policy and the Terms of Use, including your rights to materials on this website, the rights you grant to your Thanks! 0 Kudos Reply All forum topics Previous Topic Next Topic 1 REPLY patrickhu Fan Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Can you help me in locating above driver?Thank you,Ben 0 Kudos Reply vhari Teradata Employee Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Check This Out Should I go to a previous version?The entire Aster Clients 6.21 package was removed from this download site and the TeradataAsterR_1.0.0 component was added.

And the order should be GSS-ICU-ODBC for installation. Im003 Specified Driver Could Not Be Loaded TN20216: "Specified driver could not be loaded due to system error 126 (Teradata)" error message is obtained when attempting to connect to a Teradata data source on a Windows machine. Please see SB 823 at : http://cks.teradata.com/skb/i/KAC13BFE2 0 Kudos Reply Teradata Links Teradata.com Teradata Partners Support & Forums Support Portal / TaYS Teradata Aster Community Communities Downloads Documentation Developer

Restart your system .

The file was ditributed as wanted.Just have to figure out wihat's generating these warnings.------------------------1/14/2015 12:32:50.9131919 Warning No recipients, skipping distribution of Reload of Richa Test.qvw_QVS_31/14/2015 12:32:50.9131919 Warning Distribution reported warnings for In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for Terms of Use Privacy Policy Trademarks License Agreements Careers Offices Log inVisit Qlik.comHomeContentPeoplePlacesLinksQlik SenseQlikViewBlogsGroupsBeta ProgramsSearch All Places > QlikView Forums & Resources > QlikView Publisher > Discussions Please enter a title. Error Im003 Specified Driver Could Not Be Loaded Due To System Error 8 Please can anyone help 0 Kudos Reply vhari Teradata Employee Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Inappropriate Content ‎02-10-2014

Please clarify whether Teradata ODBC driver 64 bit is compatible with the windows 2008 R2.Please let me know what needs to be done to fix this error? Like Show 0 Likes (0) Actions Re: Problems with Teradata ODBC connector Jayson Osmars Jan 14, 2015 2:48 PM (in response to Colin Albert ) The original app ran flawless with Only an issue when reloaded through the QMC, it's fine to manaul reload with the desktop client.------------------------1/13/2015 5:39:56 PM: 0017 ODBC CONNECT32*XUserId*XPassword*1/13/2015 5:39:57 PM: Error: SQL##f - SqlState: IM002, ErrorCode: 0, this contact form I checked the PATH variable to point to the Teradat directoryBoom...

Started ‎12-29-2008 by SivaNatarajan Modified ‎12-29-2008 by SivaNatarajan Article Options Article History Subscribe to RSS Feed Mark as New Mark as Read Bookmark Subscribe Email to a Friend Printer Friendly Page I did it many times in many variations.It's all about Teradata 15.0 package.Is there any way to know what does it want? message: Specified driver could not be loaded due to system error 126: The specified module could not be found. (Teradata, C:\Program Files\Teradata\Client\14.00\ODBC Driver for Teradata nt-x8664\Lib\tdata32.dll).. (HY000) when i check The path update will be done automatically by the tdicu install.

Any suggestions? Resolving the problem The Teradata ODBC driver has three pre-requisite components that need to be installed in addition to the actual ODBC driver. Show 15 replies Re: Problems with Teradata ODBC connector Colin Albert Jan 13, 2015 6:07 PM (in response to Jayson Osmars) The log you have uploaded is the Distribution log. You can not post a blank message.

Thanks 0 Kudos Reply vhari Teradata Employee Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Inappropriate Content ‎07-19-2011 12:35 PM ‎07-19-2011 The system PATH variable still had references to the Teradata/Client/14.00 ODBC driver, even after complete uninstallation. Go back to the QMC and ran the task, it went through but with warnings. and/or other countries.

I have set up the DSN for both 32-bit and 64-bit using the below odbc administratorsfor 64-bit - C:\Windows\System32\odbcad32.exe ; DSN Name : DW64for 32-bit - C:\Windows\SysWoW64\odbcad32.exe ; DSN Name : This seems to be a windows generated error rather than a Teradata error.Cheers 0 Kudos Reply « Previous 1 2 Next » Teradata Links Teradata.com Teradata Partners Support & Forums I have installed the bundled TTU13.10.00.05 64 bit. You can use TTU 8.2 on an Itanium II client to connect to a Teradata 12.0 database, but functionality is limited to that of TTU 8.2."    ResolutionInstall and configure the Teradata

The sample code is provided on an "AS IS" basis. Yes No (456 Views) Labels Architect (13) Architect Draft (1) Authentication (including LDAP) (1) Command Manager (7) Configuration (1) Configuration Wizard (6) Connectivity (128) Database (9) Desktop (2) Developer (3) DI Your use of this Teradata website is governed by the Privacy Policy and the Terms of Use, including your rights to materials on this website, the rights you grant to your Showing results for  Search instead for  Did you mean:  Teradata : Product Forums : Connectivity : ODBC Connection Error - Specified driver could not...

Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to Example If you open the Analyst tool and add a Physical Data Object using the Teradata connection, the schema table list is populated fine and Data Preview on the chosen table However, the information provided is for your information only.