Action No action required. Action Contact your BEA TUXEDO system Technical Support about resetting the number of UNIX system semaphores as per the IPC tuning guidelines in the BEA TUXEDO Installation Guide. Action Contact your BEA TUXEDO system Technical Support. 427 ERROR: [Cannot find own BB entry] Description During the shutdown of a server the queue must be drained, and while the queue Action The semaphore set was somehow removed. Check This Out

In some cases the error may have more parameters in Error System Lock Semop Failure format .This additional hexadecimal code are the address of the memory locations where the instruction(s) was Action Clean up any IPC resources and re-boot the application from scratch. Action Look up the errno_val in errno.h to see its name. Contact your BEA TUXEDO system Technical Support or resource manager vendor. 467 ERROR: tpclose TPERMERR xa_close returned errstring Description The call to xa_close from within tpclose returned the XA error value

System Lock Semop Failure Errno = 22

Show him/her the error message. Action Retry the operation and if the problem persists, contact your BEA TUXEDO system Technical Support. 313 ERROR: Log warmstart can only be called by BBL Description An attempt to warmstart You may want to set the ResLogLevel of this Tuxedo resource to "TRACE" and then bring it online through VCS.

This is probably caused by an application-defined tpsvrinit function. This was requested by setting the -n option on the CLOPT option to the server in the configuration file. Check that enough shared memory has been configured. Action Check the userlog for earlier messages indicating the cause of the failure. 461 ERROR: Memory allocation failure Description An attempt dynamically to allocate memory from the operating system using malloc()

This can be caused by the inability to access the path given as the argument to the -o option. Libtux_cat:669: Error: Message Operation Failed Because Of The Invalid Message Queue Identifier Description While trying to send a meta-message, the request cannot be sent. saetechnologies.com - Colorway Wordpress Theme by InkThemes.com Raju PeopleSoft Admin Blog Home Home Hexaware Dba-Burleson Who likes this blog ? 7 May 2014 TUXLIB Errors 100-700 LIBTUX Messages 200-299 200 ERROR: If you are already using the maximum value, and if you are also using either the LOGGED value for the CMTRET keyword in the ubbconfig file or the TP_CMT_LOGGED setting for

Action The TMSs should not be shut down individually (using the -i option). Action Check the error reporting mechanism for the associated resource manager to determine the cause of the problem. The -g -l -S flags should be used instead. 430 ERROR: Application rejects shutdown request 16 Description The application has denied a shutdown request. See Also tmloadcf(1), ubbconfig(5) 343 ERROR: Could not find DBBL Description While initializing the BEA TUXEDO application, shared memory could not be allocated for the Bulletin Board.

Libtux_cat:669: Error: Message Operation Failed Because Of The Invalid Message Queue Identifier

The number of semaphores created per machine is roughly equal to the value of MAXACCESSERS on that machine. There are two (2) ways to fix Error System Lock Semop Failure Error: Advanced Computer User Solution (manual update): 1) Start your computer and log on as an administrator. 2) System Lock Semop Failure Errno = 22 This Error System Lock Semop Failure error code has a numeric error number and a technical description. Libtux_cat:271 Action Contact your BEA TUXEDO system Technical Support. 332 ERROR: Memory allocation failure Description An attempt dynamically to allocate memory from the operating system using malloc() failed.

An incomplete installation, an incomplete uninstall, improper deletion of applications or hardware. his comment is here How to easily fix Error System Lock Semop Failure error? Action Check and edit the UBBCONFIG file and make sure the FSCONFIG environment variable is set correctly. Action Contact your BEA TUXEDO system Technical Support. 297 ERROR: funcname: no space can be allocated for disk table or for VTOC/UDL Description An attempt to allocate space within the VTOC Libtux_cat:268: Error: Failed To Stop Serving

Action See the userlog for more information about this transaction's completion. This error message is issued when the RM encounters an error while processing the "forget" request. See Also ubbconfig(5) 392 INFO: GTTELOG: GTRID: machine(machine) counter_time(0xtime) counter(0xcount) 12 Description This message prints out the contents of a global transaction table entry. this contact form See Also ubbconfig(5), servopts(5) in the System/T reference manual, plock(2) in UNIX system reference manuals 258 WARN: Memory lock plock() failed Description An attempt to lock the process in core has

Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... You're now being signed in. Action Consult the time(2) manual page to determine the exact nature of the error.

See Also See Messages No. 392, 394, 395, and 396 in this chapter, and Message No. 408 in the chapter on CMDTUX messages. 394 INFO: cmchid(val) q(val2) type(val3) iter(val4) reg_index(val5) Description

The key isn't important it was probably set by the tuxedo admin.Lots of applicatoins are using semaphores and memory keys, and you'll want to make sure you have adequate space for This message is issued when a system process (for example, DBBL or BBL) initializes and its call to malloc() fails. In any case, the BBL should clean up after the process. 270 ERROR: Restart sync error errno Description An internal error occurred during a restart of a process. Action Check that the argument to the -e option of CLOPT is correct in the configuration file.

Description While initializing the application, a program found the BEA TUXEDO system semaphore existed but was not initialized within 10 seconds. See Also tmloadcf(1), ubbconfig(5) 355 ERROR: No BBL on this machine Description The process that issued this message tried to join a site that was in the midst of being shut Action Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. navigate here Action No action required.

Action Contact your BEA TUXEDO system Technical Support. 331 ERROR: No registry table entries 7 Description There are no more free entries in the registry table, so an attempt to allocate Action Check for corrupted shared memory or an invalid IPCKEY (wrong application). 19 LIBTUX Messages 500-599 500 ERROR: Invalid status given Description A status was passed to the update routine that Action Contact your BEA TUXEDO system Technical Support. 410 ERROR: [Invalid table entry information given] Description While trying to retrieve the status field entry, the tmid passed in is invalid. Action Contact your BEA TUXEDO system Technical Support or your database system vendor.

Or, this message can occur when an existing transaction tries to instantiate itself on a server's bulletin board, in which case the transaction will fail to commit. Action Contact your BEA TUXEDO system Technical Support. 330 ERROR: Invalid table type given Description An internal function has failed because it attempted to access an invalid table. See Also See Messages No. 392, 393, 395, and 396 in this chapter, and Message No. 408 in the chapter on CMDTUX messages. 395 INFO: log_page(val) version(val2) tranflags(val3) Description This message The error can occur when the server not being run as super-user, the requested lock is already on the process, or the system is out of memory.

Can you explain this to me? To unlock all features and tools, a purchase is required. Action Contact your BEA TUXEDO system Technical Support. 314 INFO: Page page skipped, chksum didn't match Description The indicated page was skipped while doing a warmstart because the checksum did not Action Check the address specified for the -Q option in the configuration file.

Or, the process sending the offending type should be altered to send a buffer that the receiver understands. Action No action required. 315 ERROR: TLOG not in an understandable format. That is, the process' type switch was not built to recognize the type and/or subtype of the message received. This is related to message 338.

See Also ubbconfig(5) 248 ERROR: System init function failed, Uunixerr = errno_val Description The server has failed to join the application. Please enter a title. This corrupted system file will lead to the missing and wrongly linked information and files needed for the proper working of the application. This means t 이 페이지를 보려면, 프레임을 볼 수 있는 브라우저가 필요합니다.

Action Change your application code to not use tpforward() in clients or outside of service routines.